ABSTRACT

Determination of the chlorine content in water from Ajali sources was carried out in the laboratory.  Chlorination has been a method for the treatment of drinking water and chlorine being an excellent disinfectant is the sole element for this practice.  The world health organization (WHO) and National Agency for Food and Drug Administration and Control (NAFDAC) set out standard chlorine adequate for drinking water which is given as 200mg/l.  This research work is based on the determination of chlorine content in raw Ajali water, treated reservoir water and Tap water. For each five samples were collected and analyzed using Mohr Method and the result for the average chlorine contents are 105.79mg/l for the Ajali raw mater, 129.70mg/l for reservoir and tap water is 178.63mg/l. In all, the results show that they correspond to the WHO/NAFDAC standard for chlorine content in drinking water.

CHAPTER ONE

1.0            INTRODUCTION

1.1     Background of the study

`        Chlorine is a greenish-yellow gas that dissolves easily in water.  It has a pungent, noxious colour that some people can perceive smell at concentrations above 0.3 part permillion.  Chlorine is an excellent disinfectant commonly added to drinking water supplies to kill harmful micro-organism.  Chlorine is not  only an effective disinfectant but it also reacts with ammoniamiron and other metal  s and  some organic compounds to improve overall water quality (white, 2000).

          In parts of the world when chlorine is not added to drinking water, thousands of people die each day from waterbone disease like typhoid and cholera according to (Darnail 1999).  However, the addition of chlorine in water has its limitations but its dangers, are relatively shortlived compared to the dangers of most other highly poisonous substances.  Rideal et al, (2005) suggests that  this is because chlorine reacts quickly with other substance in after (and  forms combined chlorine)  or escapes  as a gas into the atmosphere.  The free chlorine test measures only the amount of free or dissolved chlorine in water, but the total chlorine test measures both free and combined of chlorine.

          According to Richardson et al (2007), if the water contains a lot of decaying  materials, free chlorine can combine with them to form disinfection –by- products like  tribhalomethanes.  Though there is a limit to the use of chlorine as negative results are possible with the addition of too odour in water are often enhanced.

          Fair et al, (2000) states that less than one half (0.5mg/L) of free chlorine is needed to kill bacterial without causing water to smell or taste unpleasant. Most people cannot detect the presence of chlorine on water  amount (1.0mg/l).  although 1.0mg/l chlorine in water is not harmful to people, it does cause problems to fish and other aquatic animals when they are expose to it over along period of time.  It is very important for  water suppliers to monitor closely the level of chlorine present in the water (Hodges 1997).

RISK OF WATERBORNE DISEASE

          Where adequate water treatment is not readily available, the impact on public health can be devastating (White, 2002), would.  Worldwide, about 1.2 billion people lack access to safe drinking water and twice that number may have adequate sanitation (Christian et al, 2001).  As a result the World Health Organization (WHO) estimates that 3.4 million people mostly children die, every year from water related diseases.  Ridealetal (2005). Even where treatment is widely practiced constant vigilance is required to guard against  waterborne disease outbreaks.

          Well known pathogens such as Ecoli are easily controlled with  chlorination but  can cause deadly outbreak give condition if inadequate  or disinfection (Richardson, et al 2007).  Some emerging pathogens like osporiolianare resistance to chlorination and can appear even in high quality water supplies.  Cryptosporidium was the cause of the longest reported drink water in United state (Craun et al, 2002).  The new regulation from U.S Environmental Protection Agency will require water system to monitor cryptosporidium and adopt a range of treatment options based on source water cryptosporidium concentrations.  Most water systems are expected to meet EPA  requirement while continuing to use chlorination.

1.2            STATEMENT OF PROBLEM

There has been high prevalence of water borne disease in 
Enugu metropolis judging from the hospital statistics hence the need to know if the cause has been from the method of water treatment employed in the purification of drinking water supplied to the municipality.

1.3            AIMS  OF THE STUDY

·        To determine the chlorine content to water from Ajalli water source.

·        To compare the chlorine content in the drinking water in Enugu metropolis with World Health Organization standard.

·        The study will also evaluate the effect of bad water chlorination and the harms of indisinfecter drinking water.

1.4            SIGNIFICANCES OF THESTUDY

This research work is meant to elucidate the actual concentration of chlorine in Enugu drinking water and to make known the processes or steps taken in the treatment of the water.  Also to establish whether some prevalent disease could be traced to the way drinking water in Enugu is treated.

1.5     SCOPE OF THE STUDY

This research work is limited to the determination of the chlorine content in raw Ajalli water source the treatment of water and the tap water within Enugu.

  DOWNLOAD THE FULL PROJECT

DETERMINATION OF CHLORINE CONTENT IN WATER FROM AJALLI SOURCE

Not The Topic You Are Looking For?



For Quick Help Chat with Us Now!

+234 813 292 6373

+233 55 397 8005


HOW TO GET THE COMPLETE PROJECT ON DETERMINATION OF CHLORINE CONTENT IN WATER FROM AJALLI SOURCE INSTANTLY

  • Click on the Download Button above.
  • Select any option to get the complete project immediately.
  • Chat with Our Instant Help Desk on +234 813 292 6373 for further assistance.
  • All projects on our website are well researched by professionals with high level of professionalism.

Here's what our amazing customers are saying

Azeez Abiodun
Moshood Abiola polytechnic
I actually googled and saw about iproject master, copied the number and contacted them through WhatsApp to ask for the availability of the material and to my luck they have it. So there was a delay with the project due to the covid19 pandemic. I was really scared before making the payment cause I’ve been scammed twice, they attended so well to me and that made me trust the process and made the payment and provided them with proof, I got my material in less than 10minutes
Very Good
JONNAH EHIS
Ajayi Crowther University, Oyo
I was scared at first when I saw your website but I decided to risk my last 3k and surprisingly I got my complete project in my email box instantly. This is so nice!!!
Excellent
Samuel From Ajayi Crowther University
You guys just made life easier for students. Thanks alot iprojectmaster.com
Excellent
Abdul Mateen Iddrisu
UDS
At first I taught is a site full of fraudsters until I saw my project in my Gmail after my payment.. THANK YOU IPROJECTMASTER and May God the almighty bless u guys abundantly
Excellent
Abdulrahman Jibrin
Nti Abaji
Nice one work prompt delivery tanx
Very Good
Ibrahim Muhammad Muhammad
Usmanu danfodiyo university, sokoto
It's a site that give researcher student's to gain access work,easier,affordable and understandable. I appreciate the iproject master teams for making my project work fast and available .I will surely,recommend this site to my friends.thanks a lot..!
Excellent
Peace From Unilag
I cried not knowing how to go about my project but the day i searched online and saw iprojectmaster, i called and got my full project in less than 15minutes, i was shocked!
Excellent
MATTHEW NGBEDE
Ahmadu Bello University
I wish I knew you guys when I wrote my first degree project, it took so much time and effort then. Now, with just a click of a button, I got my complete project in less than 15 minutes. You guys are too amazing!
Excellent
Abraham Ogbanje
NATIONAL OPEN UNIVERSITY OF NIGERIA
At first I was afraid.. But I discovered they are legit. I will bring more patronize
Very Good
Oluchi From Michael Opara University
If you are a student and you have not used iprojectmaster materials, you are missing big time! iprojectmaster is the BEST
Excellent

FREQUENTLY ASKED QUESTIONS

How do I get this complete project on DETERMINATION OF CHLORINE CONTENT IN WATER FROM AJALLI SOURCE?

Simply click on the Download button above and follow the procedure stated.

I have a fresh topic that is not on your website. How do I go about it?

How fast can I get this complete project on DETERMINATION OF CHLORINE CONTENT IN WATER FROM AJALLI SOURCE?

Within 15 minutes if you want this exact project topic without adjustment

Is it a complete research project or just materials?

It is a Complete Research Project i.e Chapters 1-5, Abstract, Table of Contents, Full References, Questionnaires / Secondary Data

What if I want to change the case study for DETERMINATION OF CHLORINE CONTENT IN WATER FROM AJALLI SOURCE, What do i do?

Chat with Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

How will I get my complete project?

Your Complete Project Material will be sent to your Email Address in Ms Word document format

Can I get my Complete Project through WhatsApp?

Yes! We can send your Complete Research Project to your WhatsApp Number

What if my Project Supervisor made some changes to a topic i picked from your website?

Call Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

Do you assist students with Assignment and Project Proposal?

Yes! Call Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

What if i do not have any project topic idea at all?

Smiles! We've Got You Covered. Chat with us on WhatsApp Now to Get Instant Help: +234 813 292 6373

How can i trust this site?

We are well aware of fraudulent activities that have been happening on the internet. It is regrettable, but hopefully declining. However, we wish to reinstate to our esteemed clients that we are genuine and duly registered with the Corporate Affairs Commission as "PRIMEDGE TECHNOLOGY". This site runs on Secure Sockets Layer (SSL), therefore all transactions on this site are HIGHLY secure and safe!